Skip to main content

P&C Scope That Passes First-Time Acceptance

From a single coordination study to full end-to-end P&C delivery — one team, every vendor platform, scoped to your project.

Protection Studies

Without verified coordination settings, miscoordination surfaces during commissioning — failed witness tests, rework, and schedule days you can't get back.

Coordination settings that match your design intent — verified before energization, not discovered during commissioning.

Protective device coordination studies, relay settings calculations, and settings files for every protective device in your distribution system. Settings are peer-reviewed, traceable to your coordination study, and ready to load into the field devices.

  • Protective device coordination study report
  • Selectivity matrices for review with your design team
  • Relay settings calculations with design-basis documentation
  • Ready-to-load settings files (SEL, Woodward, ABB, multi-vendor)
  • Arc-flash incident energy recalculations reflecting final settings

“Coordination philosophy is often overlooked during construction. When the facility goes live, no one realizes the device settings don't match the client's intentions.”

— Hood Patterson & Dewar — Protection coordination white paper

Relay Programming

When multiple vendors mean multiple programming teams, finger-pointing starts at the first failed integration test — and your schedule absorbs the delay.

One team programs every relay platform on your project — consistent logic, tested configurations, no vendor finger-pointing.

Multi-vendor relay and controller programming across SEL, Woodward, CAT, ABB, and automation controllers (RTAC, easYgen, LS-6). Every logic file implements your protection and automation philosophy, configured for IEC 61850 GOOSE peer-to-peer messaging where applicable.

  • Protection relay logic files per device (SEL, Woodward, CAT, ABB)
  • Automation controller programs (RTAC, easYgen, LS-6, EMCP)
  • IEC 61850 GOOSE configuration and SCL/CID files
  • Logic validation test results for each device configuration
  • Programming submittals formatted for your review workflow

“Programming these relays is not intuitive since they use terminology that is more familiar to utility engineers than plant engineers.”

— Hallam-ICS — Relay programming technical brief

Testing & Commissioning

Commissioning without traceable test procedures means retests, punch-list surprises, and witness testing that doesn't pass on the first attempt.

Commissioning that completes on schedule without major retests — every test procedure traces to a design requirement, every expected result is documented before the test begins.

End-to-end commissioning from factory acceptance through integrated systems testing. The team that designed and programmed the system runs the commissioning — no learning curve during the most schedule-critical phase. Test records trace directly to your design requirements and ITP milestones.

  • Inspection and Test Plans (ITPs) aligned to your project milestones
  • FAT, Site Acceptance Testing (SAT), and IST test procedures — expected results pre-defined, traceable to your ITP requirements
  • Methods of Procedure (MOPs) with back-out plans for energization
  • Structured test records and punch-list resolution tracking
  • Tier certification witness testing support

“Commissioning is always the squeeze point. What started as a two-week schedule gets squeezed to three or four days.”

— Ryan Orr, Senior Consultant, Uptime Institute — Uptime Institute presentation

EPMS/SCADA Integration

Fragmented monitoring across disconnected platforms means your operations team can't correlate events during an incident — root-cause analysis takes days instead of minutes.

A single monitoring and control platform that unifies every IED, meter, and controller — with sequence-of-events resolution your operations team can actually use.

EPMS design and integration: IED connectivity, power metering, historian configuration, and operator dashboards. Protocol bridging across Modbus, DNP3, IEC 61850, BACnet, and OPC UA connects your power monitoring to BMS and DCIM platforms through defined northbound APIs.

  • EPMS architecture design with protocol mapping
  • IED and meter integration configurations
  • Historian and dashboard configuration with SOE resolution
  • DCIM and BMS northbound API integration (REST/SNMP/OPC UA)
  • Alarm rationalization and points list documentation

Not Sure Where to Start?

Bounded engagements for primes who need specialized P&C support on a compressed timeline — defined scope, clear deliverables.

Commissioning Readiness Sprint

Your commissioning window is 3–6 months out and P&C milestones are slipping.

Your commissioning date is approaching and P&C milestones are slipping — failed pre-functional tests, untested protection logic, or settings that haven't been validated against acceptance criteria. A time-boxed assessment identifies the gaps, then closes the critical ones — gap analysis, prioritized remediation plan, and executed fixes.

Start a Conversation

P&C Architecture Review

You're in design phase and want an independent architecture review before you commit.

Your P&C architecture has unresolved questions — single points of failure, untestable protection paths, or coordination gaps that won't survive witness testing. An independent FMEA-based assessment surfaces them before you commit to commissioning.

Start a Conversation

Rescue Engagement

Your P&C sub fell through — commissioning is weeks away and LDs are on the table.

A P&C scope has gone sideways — the original integrator underperformed, the schedule is blown, and liquidated damages are looming. Current-state assessment, recovery plan, and execution. Fixed-fee where scope is bounded; T&M with caps where discovery is needed.

Start a Conversation

We focus exclusively on specialist protection & controls scope for Tier III/IV data centers. If your project needs general electrical contracting or commodity panel builds, we're happy to refer you to firms that specialize in those areas.

Define Your Scope

Let's Turn Your Requirements Into Deliverables

Book a scoping call to define your protection and controls deliverables. Still mapping the right support model? Complementary services are below.

Additional Engineering Services

These services complement your core P&C scope — available standalone or bundled with protection, relay, commissioning, or SCADA work above.

Featured scope

End-to-End P&C Scope

One subcontract covers design through acceptance — no coordination risk between separate design, programming, and commissioning teams.

Full-scope protection and controls delivery from feasibility through commissioning and release to service — single point of accountability across every phase. We carry the P&C risk during cutover and go-live. The team that designed the logic stands beside you during the acceptance test, so issues get resolved on the spot.

  • Basis of Design and Functional Design Specifications
  • Complete relay and controller programming across all platforms
  • Commissioning procedures and execution (FAT through IST)
  • As-built documentation package for owner handover
  • Submittals and RFI responses aligned to your project workflow

Additional Specialized Services

Open only the services that round out your engagement. These are specialist add-ons and standalone scopes for owners or primes who need a narrower solution than full-scope delivery.

Additional service

Architecture & Design

A controls architecture with no untestable failure modes — designed so every protection scenario can be validated before commissioning begins.

Power system control architecture design for Tier III/IV data centers using Distributed Control Architecture methodology. Control philosophy, OT network architecture, and FMEA-based failure response mapping — the blueprint your facility's protection and control systems build from.

  • Basis of Design narrative with control philosophy
  • Functional Design Specifications with sequences of operation
  • Cause-and-effect matrices for normal, emergency, and maintenance modes
  • OT network architecture design (PRP, VLAN segmentation, IEC 62443 zones/conduits)
  • FMEA analysis identifying failure modes and protection responses

Additional service

Power Studies

Study reports with actionable mitigations and ready-to-load settings — not shelf-ware that needs a second round of engineering to implement.

Power system studies: load flow, short-circuit, arc-flash, harmonics (IEEE 519), and grounding analysis (IEEE 80). Results feed directly into protection coordination and relay settings — no second round of engineering between study findings and field implementation.

  • Load flow and short-circuit analysis reports
  • Arc-flash hazard analysis with incident energy labels
  • Protection coordination study with time-current curves
  • Harmonics analysis per IEEE 519 compliance
  • Ready-to-load relay settings files derived from study results

Additional service

Cybersecurity

An OT security posture that satisfies your client's requirements and insurer expectations — designed into the architecture, not bolted on after commissioning.

IEC 62443-aligned security architecture for OT environments: zone and conduit modeling, hardening baselines, industrial firewalls, and secure remote access — designed into the controls architecture, not added as a post-commissioning overlay.

  • IEC 62443 zone and conduit model
  • Device hardening baselines and configuration standards
  • Secure remote access architecture
  • Asset inventory and vulnerability management framework
  • Incident response runbooks tailored to OT environments

Additional service

Modernization & Migration

Legacy system replacement executed with zero or minimal downtime — protecting your client's operations while extending system capability.

Brownfield modernization for data centers with aging or undocumented protection and controls systems. Current-state audit, staged migration plan with rollback procedures, and cutovers executed using temporary bridging logic validated during live board-by-board production cutovers.

  • Current-state audit and gap analysis report
  • Staged migration plan with rollback procedures
  • Temporary bridging logic for live cutover periods
  • Updated documentation and as-built drawings
  • 5-10 year technology evolution roadmap

Additional service

Lifecycle & Managed Services

Ongoing support from the team that built your system — no re-learning curve when issues arise or re-certification comes due.

Post-commissioning managed services: remote monitoring architecture, periodic re-certification testing, firmware and patch management, and obsolescence tracking. Same team from commissioning stays with you through the operational lifecycle.

  • Remote monitoring architecture design and diagnostic support
  • Periodic re-certification test procedures and execution
  • Firmware and patch management with scheduled maintenance windows
  • Obsolescence tracking and migration roadmaps

Additional service

Training

Operators and maintenance staff who understand the system they're running — not just which buttons to press, but why the protection logic works the way it does.

Operator and maintenance training: classroom instruction, hands-on simulation exercises, alarm rationalization walkthroughs, and train-the-trainer modules. All training is built around your facility's specific configuration and operating procedures.

  • Classroom training materials customized to your system
  • Simulation-based exercises for abnormal and emergency scenarios
  • Train-the-trainer modules for your operations staff
  • Alarm rationalization guide and HMI philosophy documentation

Let's Scope Your P&C Deliverables

Tell us about your project and we'll define the protection & controls scope that fits.

For procurement: Download our capability statement